BRKT
7-47
6S35H11
Bracket unit
8.
Check the fluid level when the rams are
fully extended. If the fluid level is low, add
sufficient fluid, and then repeat step 7.
Bleeding the PTT unit (built-in)
1.
Fully tilt the outboard motor up and down
a few times.
NOTE:
Connect the PTT motor leads to the battery
terminals, without installing the power unit. To
connect the PTT motor leads, see “Bleeding
the PTT unit.”
2.
Let the fluid settle for 5 minutes.
3.
Push and hold the PTT switch in the up
position until the outboard motor is fully
tilted up.
4.
Support the outboard motor with the tilt
stop lever, and then let the fluid settle for
5 minutes.
w
After tilting up the outboard motor, be
sure to support it with the tilt stop lever.
Otherwise, the outboard motor could sud-
denly lower if the PTT unit should lose
fluid pressure.
5.
Remove the reservoir cap
1
, and then
check the fluid level in the reservoir.
NOTE:
If the fluid is at the correct level, the fluid
should overflow out of the filler hole when the
cap
1
is removed.
6.
If the fluid is below the correct level, add
fluid of the recommended type.
7.
Install the new O-ring reservoir cap, and
then tighten it to the specified torque.
NOTE:
Repeat this procedure until the fluid remains
at the correct level.
6S370510
6S370520
1
Reservoir cap
1
:
7 N·m (0.7 kgf·m, 5.2 ft·lb)
6S35H11_072 05.9.9 0:42 Page 48
Summary of Contents for 250GETO
Page 1: ...L250G SERVICE MANUAL 6S3 28197 5H 116 250G 250G L250G ...
Page 4: ......
Page 135: ... MEMO 9 8 7 6 5 4 3 2 1 6S35H11 5 48 ...
Page 201: ...6S35H11 6 64 9 8 7 6 5 4 3 2 1 MEMO ...
Page 291: ......
Page 292: ...YAMAHA MOTOR CO LTD Printed in Japan Aug 2005 1 4 1 E_2 Printed on recycled paper 250G L250G ...