VR-160 O
PERATING
M
ANUAL
53
S
CANNING
P
RIORITY
C
HANNEL
S
CANNING
(
D
UAL
W
ATCH
)
The
VR-160
’s scanning features include a two-channel scanning capability, which allows
you to operate on a VFO or Memory channel, while periodically checking a user-defined
Memory Channel for activity. If a station is received on the Memory Channel which is
strong enough to open the Squelch, the scanner will pause on that station in accordance
with the Scan-Resume mode set via Set Mode Item 75:
SCN.RSM
. See page 56.
Here is the procedure for activating Priority Channel Dual Watch operation:
1.
Press the [
V/M
] key momentarily to enter the Memory Recall mode, if you are not
using memories already.
2.
Press and hold in the [
F/W
] key for one second, then rotate
DIAL
knob to select the
memory channel you wish to be the “Priority” channel.
Note
: Do not forget to pull the
DIAL
knob to rotate the
DIAL
knob.
3.
Press the [
BAND
] key. The “
PRI
” icon will appear above of the
volume level indicator, indicating it is the Priority channel.
4.
Now set the
VR-160
for operation on another memory channel,
or on a VFO frequency.
5.
Press and hold in the [
V/M
] key for one second. The display will remain on the VFO or
memory channel selected. However, the “
DW
” icon will appear
on the display, and every five seconds the
VR-160
will check the
Priority Channel for activity. If a station appears on the Priority
Channel, the radio will pause on that channel, as described pre-
viously.
The receiving time interval (ratio) between the current channel (or VFO frequency) and
Priority channel may be customized via Set Mote Item 65:
PRI.TMR
.
To set the receiving time interval:
1.
Press and hold in the [
BANK
] key for one second to enter the Set mode.
2.
Rotate the
DIAL
knob to select Set Mode Item 65:
PRI.TMR
.
Note
: Do not forget to pull the
DIAL
knob to rotate the
DIAL
knob.
3.
Press the [
BANK
] key momentarily to enable adjustment of this
Set Mode Item.
4.
Rotate the
DIAL
knob to select the desired time interval. Avail-
able selections are
0.1S
-
0.5S
(0.5S/step) and
1.0S
-
10S
(0.5S/
step).
5.
When you have made your selection, press the
PTT
switch to save the new setting and
exit to normal operation.
The default condition for this Set Mode Item is “5.0S.”
Summary of Contents for VR-160
Page 57: ...VR 160 OPERATING MANUAL 55 NOTE...
Page 97: ...VR 160 OPERATING MANUAL 95 NOTE...