en – Original instructions
17
• Directive 2014/34/EU of 26 February 2014
(equipment intended for use in potentially
explosive atmospheres)
• 2014/30/EU Directive of 26 February 2014
(electromagnetic compatibility) and subsequent
amendments
• 2011/65/EU Directive of 8 June 2011
(restriction of the use of certain hazardous
substances in electrical and electronic
equipment) and subsequent amendments.
6. References to the relevant harmonized
standards used or references to the other
technical specifications, in relation to which
conformity is declared:
• Pump: EN 1127-1:2011, EN 15198:2007, EN
ISO 80079-36:2016, EN ISO 80079-37:2016;
Electric motor: refer to electric motor
manufacturer’s declaration of conformity
included in the supply.
• Refer to electric motor manufacturer’s
declaration of conformity included in the supply.
• EN 50581:2012.
7. Notified body:
(ATEX)
Pump: SGS Baseefa Limited (NB 1180)
performed the EU-type examination and issued
the certificate Baseefa16ATEX0067X;
Electric motor: refer to electric motor
manufacturer’s declaration of conformity
included in the supply.
Additional information:
(ATEX) The following specific conditions of
use apply.
- The equipment must be suitably earthed prior
to operation.
- It is the user’s responsibility to ensure the
equipment does not run dry. Any control
system used to achieve this must comply with
the relevant requirements of EN 80079-37.
- The equipment may only be operated when it
is filled with the liquid to be pumped.
- The liquid to be pumped must have
conductivity >1000 pS/m (CLC/TR 60079–32–
1:2015)
- For T4 operation the maximum temperature of
the liquid to be pumped must not exceed 90°C.
Pump:
II2G Ex h IIC T4 Gb -
10°C≤ Tamb
≤+55°C
Electric motor: see the motor data plate.
(RoHS) Annex III - exemptions - 6a), 6b), 6c).
Signed for and on behalf of: Xylem Service Italia S.r.l.
Montecchio Maggiore, 11/09/2019
Amedeo Valente
(Director of Engineering
and R&D)
rev.01
Lowara is a trademark of Xylem Inc. or one of
its subsidiaries.
2
Handling and storage
2.1 Inspect the delivery
1.
Check the outside of the package for evident
signs of damage.
2. If the product bears visible signs of
damage, notify our distributor within
eight days from the delivery date.
Unpacking the unit
1. Follow applicable step:
-
If the unit is packed in a carton, then
remove the staples and open the carton.
-
If the unit is packed in a wooden crate,
then open the cover while paying
attention to the nails and straps.
2. Remove the securing screws or the straps from
the wooden base.
2.1.1
Inspection of the unit
1.
Remove the packaging material from the
product.
Dispose of all packing materials in accordance
with local regulations.
2. Inspect the product to determine if any parts
have been damaged or are missing.
3. If applicable, unfasten the product by removing
any screws, bolts, or straps.
4.
For your personal safety, be careful when you
handle nails and straps.
5. Contact the local sales representative if there is
any issue.
2.2 Guidelines for transport
Precautions
WARNING:
•
Observe the accident
prevention regulations in
force.
•
Risk of crushing. The unit and
the components can be
heavy. Implement proper
lifting methods and always
wear steel-capped boots.
Check the gross weight marked on the packaging in
order to choose suitable lifting equipment.
Installation and securing
The pump or pump unit can be transported only
horizontally. Make sure that the pump or pump unit
is securely fastened during transportation and
cannot roll or fall over.
WARNING:
Do not use eyebolts screwed on the
motor for handling the whole pump
unit.
Do not use the shaft end of the pump
or of the motor to move the pump, the
motor or the unit.
Summary of Contents for LOWARA ESHS ATEX