3500 Series Flat Panel Industrial PC
74
13.
Insert the new bulb assembly, and fasten the screw to secure.
Note
Xycom Automation recommends replacing both bulbs at the same
time.
14.
Reverse steps 1 through 10 to reassemble the unit.
3512KPM, KPT, KPMT TFT Flat-Panel Display (Sharp #LQ12S41)
1.
Turn off the power source.
2.
Unlatch and remove the lid.
3.
If a touch screen is installed, disconnect the touch screen cable (TCH1).
4.
Disconnect the KEYPAD1, LEDKB1, and MS2 connectors.
5.
Set the unit with the front panel facing down, and remove the four screws holding
the front panel to the display adapter plate.
6.
Flip the unit over, lift off the front panel, and set it aside.
7.
Unscrew the four screws that attach the adapter plate to the standoffs.
8.
Unscrew the four screws that attach the flat-panel display to the inner set of
standoffs.
9.
Disconnect the bulb connectors from the inverter.
10.
Gently lift the right side of the flat-panel display, and disconnect the data interface
connector (on the left side).
11.
Lay the flat-panel display facedown on a protective surface.
12.
Referring to Figure D-4, push in the tab at the end of the display with a flat-bladed
screwdriver, and slide the bulb assembly out.