Appendix V: Restoring Defaults from the Front Panel or App
Using the Configuration App
Pressing the “Reset Defaults” will set all the adjustable parameters in the app back to their
default values but
remember to press “Set to Unit”
to update the unit with these settings!
From the Front Panel
If you’re unsure about the internal setup of the unit and don’t have access to the app, but need
a known starting point for use, it is also possible to reset to defaults via a front panel button
sequence.
Power up while holding in Meter Outs + Select Source Type (Analogue/AES/Dante) in the Line
Monitoring Section.
Wait for the relays to engage with a click and the unit is reset to the following settings:
AES Output Clock: 96kHz
3
External Sync: Use if Valid
3
AES Mode on inputs 3&4 for all sets: Normal operation
3
Dante Auxiliary Bus Inputs: Ignored
4
(will still appear in Dante Controller but will not be routed to Mains outputs)
GPI ports: Both disabled
Hint — you will know when the GPI ports are disabled as the buttons for mic/line options are
functional again!
Copyright XTA Electronics 2020 Rev 1.03
3
MX24-A only
4