Page 30
MX Series — MX24 Operating Instructions
ta
x
GPI Input 1 can be configured to either provide a system mute of the main outputs, or to route
the mic input to selected outputs.
Choose “Microphone Evac. To Main Outputs” to access the other available options as per the
front panel - the mic gain, the filter setting, 48V and the routing required.
The line input is similarly configured for use with the GPI Input 2.
The time to fade down the current console selection setting can also be preset from 0.5
seconds to 10 seconds in the “Evac. Options” section.
If both the Microphone and Stereo Line inputs are configured to be GPI triggered, it is
possible to force the Mic on GPI Input 1 to be higher priority if required, also under the “Evac.
Options”.
Once everything is set up as required, press “Set to Unit” and these settings will take effect —
all parameters configured will immediately be updated and show on the front panel (apart
from the gain knob which won’t move!).
Note that configuration of the Mic or Line inputs for voice evac purposes disables the front
panel controls for that section.
To quickly reset these options from the app or the front panel please see Appendix V on page
41.