MX Series — MX24 Operating Instructions
Page 19
ta
x
Line Monitoring
1: Source Select: Choose to monitor the A or B input set, or the final outputs (monitor point in
green in diagram below) and then…
2: Type Select: …chosen source type (Analogue or Digital which will be AES or Dante
depending on the model) for the set. When “OUTS” is selected, source type is disabled as
both types are fed simultaneously. There is an “OFF” state for this selection which selects
monitoring from the “Pre Console Select” points in red in the signal path as below:
This point allows monitoring of the actual choice of Primary and Failover selections and
verification that the failover is working as expected (by deliberately disconnecting/inducing a
failover situation and listening to the swap to the backup source).
3: Channel Select:…which channel from the chosen set to monitor.
4: Headroom Meter: This meter shows the level of the currently selected channel.