9
◼
Servo Drive Orientation
Install the servo drive perpendicular to the wall so the front panel containing connectors faces outward.
◼
Cooling
As shown in the figure above, allow sufficient space around each servo drive for cooling by cooling fans or
natural convection.
◼
Side-by-side Installation
When install servo drives side by side as shown in the figure above, make at least 10mm between and at least
50mm above and below each servo drive. Install cooling fans above the servo drives to avoid excessive
temperature rise and to maintain even temperature inside the control panel.
◼
Environmental Conditions in the Control Panel
⚫
Servo driver working ambient Temperature: -10~40
℃
⚫
Humidity: 90%RH or less
⚫
Vibration: 4.9m/s
2
⚫
Condensation and Freezing: None
Note: when installing horizontally (mask facing the operator), it needs to use the frame provided by our company