Zynq-7000 AP SoC and 7 Series FPGAs MIS v4.1
113
UG586 November 30, 2016
Chapter 1:
DDR3 and DDR2 SDRAM Memory Interface Solution
Injecting faults should be performed in a critical region in software; that is, writing this
register and the subsequent write to the memory must not be interrupted.
Special consideration must be given across FI_D0, FI_D1, FI_D2, and FI_D3 such that only a
single error condition is introduced.
FI_D3
Note:
This register is only used when DQ_WIDTH =144.
This register is used to inject errors in data (Bits[127:96]) written to memory and can be
used to test the error correction and error signaling. The bits set in the register toggle the
corresponding data bits (word 3 or Bits[127:96]) of the subsequent data written to the
memory without affecting the ECC bits written. After the fault has been injected, the Fault
Injection Data register is cleared automatically.
The register is only implemented if C_ECC_TEST = “ON” or ECC_TEST_FI_XOR = “ON” and
ECC = “ON” in a MIG design in the Vivado Design Suite.
Injecting faults should be performed in a critical region in software; that is, writing this
register and the subsequent write to the memory must not be interrupted.
FI_ECC
This register is used to inject errors in the generated ECC written to the memory and can be
used to test the error correction and error signaling. The bits set in the register toggle the
corresponding ECC bits of the next data written to memory. After the fault has been
injected, the Fault Injection ECC register is cleared automatically.
The register is only implemented if C_ECC_TEST = “ON” or ECC_TEST_FI_XOR = “ON” and
ECC = “ON” in a MIG design in the Vivado IP catalog.
Injecting faults should be performed in a critical region in software; that is, writing this
register and the subsequent write to memory must not be interrupted.
Table 1-46:
Fault Injection Data (Word 2) Register Bit Definitions
Bits Name
Core
Access
Reset
Value
Description
31:0
FI_D2 W
0
Bit positions set to 1 toggle the corresponding Bits[95:64] of
the next data word written to the memory. This register is
automatically cleared after the fault has been injected.
Table 1-47:
Fault Injection Data (Word 3) Register Bit Definitions
Bits
Name
Core Access
Reset Value
Description
31:0
FI_D3 W
0
Bit positions set to 1 toggle the corresponding
Bits[127:96] of the next data word written to the
memory. The register is automatically cleared after
the fault has been injected.