28
ML628 IBERT Getting Started Guide
UG806 (v1.0) May 20, 2011
Running the GTX IBERT Demonstration
3.
In the project panel, double-click
IBERT Console
).
4.
At the top of the ChipScope Pro analyzer window, click the
Reset All
button
(
).
5.
When prompted “Are you sure you want to reset all Channels and Counters?” Click
Yes
.
Viewing GTX Transceiver Operation
After completing
in
Starting the SuperClock-2 Module
, the IBERT demonstration is
configured and running. The status and test settings are displayed on the
MGT/IBERT
Settings
tab in the IBERT Console shown in
.
Note the line rate, TX differential output swing, and RX bit error count:
•
The line rate for all four GTX transceivers is 6.5 Gps (see
MGT Link Status
in
).
•
The GTX transmitter differential output swing is preset to 590 mV.
•
Verify that there are no bit errors.
X-Ref Target - Figure 1-33
Figure 1-33:
Project Panel - IBERT Console (GTX)
X-Ref Target - Figure 1-34
Figure 1-34:
Reset All Button
UG
8
06_c1_17_041411
UG
8
06_c1_34_041411