Operation, Rack and Digital HPAs
Non-latched Fault Report Displays
See Figure 17. Non-latched faults clear when the fault condition
occurs. The non-latched fault report
does not
clear when the
fault clears. Operator action is required to reset the fault report
display. The operator clears a non-latched fault report display by
returning to a previous menu. The operator can elect to:
•
For a persistent fault, go to a previous menu for the faulted function
(e.g., set maximum power trip level), change the mode from fault to
alarm and adjust the amplifier output to a new value.
•
Respond to the fault report and correct the fault condition (e.g.,
correct prime power to alleviate a low-line condition).
•
For a known cause such as a transient line-voltage dip, go to a
previous menu to reset the fault report display, and then take no
further action.
Three of the fault monitors (Maximum Power Fault, Minimum
Power Fault, and Maximum Reflected Power Fault) are optional
and can be enabled or disabled by the operator.
Figure 17, Non-Latched Fault Report Displays
Menutrees
The menutrees for the XTRD Series Amplifier Digital M&C
System are presented on individual pages so that you may
remove and copy them for ready reference. See Figure 18 ",
Menutree Sheet 1 of 3", Figure 19 , Menutree Sheet 2 of 3, and
Figure 20 , Menutree, Sheet 3 of 3.
Summary of Contents for XTU-400K
Page 10: ...MNC 0000 010 2 of 10 Revision A7...
Page 38: ...Safety Sicherheit MNC 0200 001 14 of 14 Revision E...
Page 60: ...Unpacking and Installation TWTA Octagon CPU MNC 0300 003 22 of 22 Revision N...
Page 66: ...MNC 0400 001 6 of 54 Revision G Operation Rack and Digital HPAs...
Page 90: ...MNC 0400 001 30 of 54 Revision G Operation Rack and Digital HPAs Figure 11 Setup Menu 2...
Page 97: ...MNC 0400 001 37 of 54 Revision G Operation Rack and Digital HPAs...
Page 101: ...MNC 0400 001 41 of 54 Revision G Operation Rack and Digital HPAs...
Page 114: ...MNC 0400 001 54 of 54 Revision G Operation Rack and Digital HPAs...
Page 150: ...MNC 0500 002 36 of 36 Revision H Amplifier Communication and Protocol Octagon ISA CPU...
Page 162: ...MNC 0700 001 6 Revision F Service and Repair...
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ......
Page 177: ......
Page 178: ......
Page 179: ......
Page 180: ......
Page 181: ......