MNC-0500-002
32 of 36
Revision H
Amplifier Communication and Protocol, Octagon ISA CPU
Waveguide Switch Control
Command Byte:
‘U’
Format:
‘U1’ Activate override mode and switch in amplifier
‘U0’ Activate override mode and switch in other amplifier
‘UM’ Activate overide mode
‘UA’ Terminate overide mode, activating automatic mode
NoteS: When sending a ‘U1’ or ‘U0’ command, also send a ‘UM’ command to the other
amplifier to prevent unwanted automatic-mode switches.
Compatibility:
For Redundant ODUs only
Time and Date
Command Byte:
‘%’
Function:
Sets the Amplifier internal clock. The clock is referenced when time
stamping faults as they are written to the Fault Log.
Parameter:
“YYYY/MM/DD, hh:mm”
Example:
2002/02/08, 13:01
YYYY = 2002
MM = 02
DD = 08
hh = 13
mm = 01
Notes:
(1) The hours are in 24 hour format.
(2) This command is not available in all amplifiers. If your amplifier does not support
this command, you will receive a rejected code “a” upon sending this command.
Summary of Contents for XTU-400K
Page 10: ...MNC 0000 010 2 of 10 Revision A7...
Page 38: ...Safety Sicherheit MNC 0200 001 14 of 14 Revision E...
Page 60: ...Unpacking and Installation TWTA Octagon CPU MNC 0300 003 22 of 22 Revision N...
Page 66: ...MNC 0400 001 6 of 54 Revision G Operation Rack and Digital HPAs...
Page 90: ...MNC 0400 001 30 of 54 Revision G Operation Rack and Digital HPAs Figure 11 Setup Menu 2...
Page 97: ...MNC 0400 001 37 of 54 Revision G Operation Rack and Digital HPAs...
Page 101: ...MNC 0400 001 41 of 54 Revision G Operation Rack and Digital HPAs...
Page 114: ...MNC 0400 001 54 of 54 Revision G Operation Rack and Digital HPAs...
Page 150: ...MNC 0500 002 36 of 36 Revision H Amplifier Communication and Protocol Octagon ISA CPU...
Page 162: ...MNC 0700 001 6 Revision F Service and Repair...
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ......
Page 177: ......
Page 178: ......
Page 179: ......
Page 180: ......
Page 181: ......