4-56
Xerox Internal Use Only
Phaser 6500/WorkCentre 6505 Service Manual
General Troubleshooting
Page Margin 2
(mm)
Sets the page margin that allows a
larger-than-standard size document
to be handled as a standard size
document. The document is reduced
to the standard size, by the set value.
Values range from 0 to 127. When the
value is 10, the margin is 10 mm.
Valid when the Discard Size setting in
Fax Setting is “On”
Extel Hook
Thresh
Sets the threshold of ON HOOK
detection at the external telephone to
one of Lower, Normal, and Higher.
Dis DP 20PPS
Sets whether or not to enable 20PPS
dial pulse. When 20PPS is disabled in
this menu, any 20PPS setting in other
menu will be overridden with 10PPS.
CNG Detect
(0.1s)
Sets the CNG detection duration for
telephone-Fax switching. Values
range from 0 to 255. When the value
is 100, the detecting time is 10 sec.
Auto Answer
(1.0s)
Sets the ring tone duration of the
external telephone terminal for Fax-
telephone switching. Values range
from 0 to 255. When the value is 100,
the duration is 100 sec.
Num Check
(1.0s)
Sets the autodialing delay duration
when different sets of document data
bound for the same destination are
placed consecutively in the
transmission queue. This pause allows
the receiving side to make time for
processing.
Values range from 1 to 255. When the
value is 10, the pause is 10 sec.
Off Hook LCS
Rate (%)
Sets the threshold of off hook
detection at LCS. Values range from 1
to 100.
Dial tone TO
(1.0s)
Sets the time out for detecting the
dial tone. Values range from 0 to 255.
When the value is 10, the dial tone
detect duration is 10 sec.
On Hook Detect
(20ms)
Sets the detecting duration for a valid
on hook signal. Values range from 10
to 255. When the value is 10, the
duration is 200 msec. Any on hook
signal shorter than the set time is
invalid.
Dis Dial tone
Sets whether or not to enable dial
tone pattern detection.
Dial tone Min
(10ms)
Sets the minimum limit of dial tone
pattern detection duration.
Dial tone Max
(10ms)
Sets the maximum limit of dial tone
pattern detection duration.
Test
Control Panel Display
Test Description