Service Guide
27
System controller board diagnostic error codes
Code
Test
Possible Cause
1
Memory
Bad memory DIMMs
2
Memory Speed
Bad DIMMs or system controller board
3
CPU Tick
Bad system controller board
4
System Timer
Bad system controller board
5
BX Host Bridge
Bad system controller board
6
PIIX4 PCI-ISA Bridge
Bad system controller board
7
21152 PCI-ISA Bridge
Bad system controller board
8
PCI-PCI Bridge
Bad system controller board
9
IX
Bad system controller board
10
Parameter Flash R/W
not implemented
11
Strata Flash R/W
not implemented
12
Strata Flash Boot Block
Integrity
Bad system controller board
13
Strata Flash File System
Integrity
Bad system controller board
14
STE100
Bad system controller board
15
VX2b-0
Bad system controller board
16
VX2b-1
Bad system controller board
17
VX2b-2
Bad system controller board
18
VX2b-3
Bad system controller board
19
Disk Identify
Bad hard disk drive
20
Disk Read/Write
Bad hard disk drive
21
Disk Read Capability
Bad hard disk drive
22
Disk Write Capability
Bad hard disk drive
23
Disk Data Format Check
Bad hard disk drive
Summary of Contents for 2135DX - Phaser Color Laser Printer
Page 73: ......
Page 93: ......
Page 97: ......
Page 99: ......
Page 165: ......
Page 174: ...Service Guide 161 Figure 4 Printer chassis FRUs 2 of 2 3 4 1 2 9 7 10 6 11 8 5 12 0725 04 13...
Page 176: ...Service Guide 163 Figure 5 Paper tray and paper tray guides FRUs 7 4 2 1 0725 05 5 6 3 8 9...
Page 180: ...Service Guide 167 Figure 8 LowerTray Assembly FRUs 1 2 5 6 7 8 9 3 4 4 4 0725 07...
Page 185: ......
Page 197: ...NOTES...
Page 198: ...NOTES...
Page 199: ...NOTES...