Installation
975-0126-01-01
27
6. Before proceeding, check that the cable polarity is correct: POSITIVE (+) on
the inverter/charger is connected to the POSITIVE (+) on the battery, and
NEGATIVE (–) cable is connected to the NEGATIVE (–) terminal on the
inverter/charger.
7. Connect the other end of the cable to the NEGATIVE (–) terminal on the
battery.
8. Use a wrench to tighten the bolt to a torque of 15–16 ft-lbs (20.4–21.7 Nm
)
at
the inverter/charger
end.
9. Attach the DC terminal covers using the screws provided to protect the DC
terminals, as shown in Figure 8.
The completed DC terminal wiring with covers is shown in Figure 9.
Figure 7
DC Cable Connections
Important:
The next step is the last cable connection you need to make. A spark is
normal when this connection is made.
Figure 8
DC Terminal Covers