Reconnect the battery cable terminals to the battery cable lugs and tighten to
battery manufacturer’s specifications. If you do not have a torque wrench, use an
appropriate tool to tighten the bolts reasonably snug. Do not over-tighten.
Reducing corrosion
on battery terminals
After tightening the cables, evenly coat all of the exposed metal surfaces of the
battery terminals and cable lugs with liquid neoprene (liquid electrical tape). Do
not apply anything between the battery terminal and the cable lugs; the connection
should be metal to metal.
The liquid neoprene cures to form an airtight protective layer and reduce the
amount of corrosion on the battery terminals. If liquid neoprene is not available,
use a light coating of white lithium grease or other sealant.
Battery Cables
Inspect all of the battery cables for missing or damaged insulation or loose
connections. Inspect any openings that the cables pass through. All such openings
must be equipped with a rubber grommet or conduit to prevent chafing on the
battery cable. If necessary, replace worn grommets. If the cable insulation is worn,
replace the battery cables.
Summary of Contents for RS2000
Page 1: ...RS2000 Sine Wave Inverter Charger Installation Guide RS2000...
Page 2: ......
Page 3: ...RS2000 Sine Wave Inverter Charger Installation Guide...
Page 8: ...iv 975 0126 01 01...
Page 16: ...xii...
Page 18: ...xiv...
Page 49: ...Installation 975 0126 01 01 31 Figure 12 Connecting the BTS Cable to Battery Temp jack...
Page 56: ...Installation 38 975 0126 01 01 Figure 15 Inverter Charger Dimensions...
Page 75: ......