28
Freedom SW 230V Owner’s Guide
Operating the Freedom SW with the SCP
Reading the System Status Screen
The
System Status
screen displays:
•
Battery-related information (see Line 2)
•
Battery level and inverter/charger operating state (see Line 3)
•
Load information (see Line 4)
•
AC Input information (see Line 5)
System Status
menu
EnInv
EnChg
Shr
Battery
BatLev
Load
AC In
24.2V -128A 29
”
C
Invert
230V 10A 6A
0V 0A 0A
Menu arrow indicates the
Enter
button. Pressing
Enter
displays
the Select Device menu.
Line 1
Line 2
Line 3
Line 4
Line 5
Field 1 Field 2 Field 3
Field 4
Field 5
Field 6
Field 8
Field 9
Field 10
Field 7
Field 11
Table 2
System Status Screen
Line 1
Label
: “
System Settings
”
Line 2
Label
:
Battery
Field 1
: Battery voltage
Field 2
: Total battery current. Negative value if the battery is discharging and
positive value when charging.
Field 3
: Battery temperature
a
. Also, displays the highest temperature between
stacked inverters that are installed.
a. The unit of temperature can be changed in the SCP Config menu screen.
Line 3
Label
:
BatLev
Field 4
: Displays a bar graph showing the approximate battery level.
Field 5
: Freedom SW inverter/charger operating state
Line 4
Label
:
Load
Field 6
: Inverter output voltage at load terminals of the inverter/charger. Voltage
is reported by the Master unit if more than one inverter/charger is installed.
Field 7
: Master current
b
Field 8
: It displays Slave current
c
.
b. When in a stacked inverter configuration.
c. In a single unit setup, the Slave will display 0A all the time mainly because of the absence
of a second unit. If two units are stacked, the Master and Slave current will display the appro-
priate current values.
Line 5
Label
:
AC In
Field 9
: AC input voltage at AC In terminals of the inverter/charger. Voltage is
reported by the Master unit if more than one inverter/charger is installed.
Field 10
: Master current
b
Field 11
: It displays Slave current
c
.
FSW 230V Owners Guide.book Page 28 Tuesday, August 7, 2018 9:38 AM
Summary of Contents for Freedom SW 230V 815-3524-02
Page 2: ...FSW 230V Owners Guide book Page ii Tuesday August 7 2018 9 38 AM...
Page 10: ...FSW 230V Owners Guide book Page viii Tuesday August 7 2018 9 38 AM...
Page 14: ...FSW 230V Owners Guide book Page iv Tuesday August 7 2018 9 38 AM...
Page 98: ...FSW 230V Owners Guide book Page 84 Tuesday August 7 2018 9 38 AM...
Page 103: ...FSW 230V Owners Guide book Page i Tuesday August 7 2018 9 38 AM...