Page: 36
SmartPad LCD
© 2003 Xantech Corporation
Figure 24
RS232 Palette Editor Window
Figure 25
Entering RS232 Command Strings
T
ESTING
RS232 C
OMMAND
S
TRINGS
There are two methods of testing RS232 Command Strings directly from the RS232 Palette Editor: One is
directly out of the PC’s Comport and the second method is through the SPLCD’s RS232 Com Port –
Figure 3
Item #21
. Using both methods you can control the component or device directly for confirmation of command
string or send the command to an RS232 Utility programming to verify proper output (this is good for Trouble
Shooting purposes or for testing the program without the component or device present).
Using PC TEST:
1. Connect the Com Port of the PC running Dragon Drop-IR SPLCD to the corresponding component
or device of the commands to be tested.
NOTE:
A “Null Modem” cable may be necessary for communicating with the Component or Device.
Please check with the Manufacturer to see if this is required.
2. Click on the ‘PC Test’ button in the RS232 Palette Editor.
3. Make sure the RS232 Port Settings are set appropriate for the device connected to (refer to the
mfg’s Instruction Manual of the component or device being tested for the proper communication
settings)
4. Click on the command string to be tested on the left-hand side of the RS232 Palette Editor.
Note:
Only commands with the
icon will be able to be tested.
5. The Device or Component connected should respond accordingly. If not, check the command string
entered and port settings in the Test RS232 Settings window. If still having problems see the
Trouble Shooting section to verify RS232 communication.
6. Test all Command Stings in this fashion before placing into a Palette File.
Using SPLCD TEST:
NOTE: The PC running Dragon Drop-IR (SPLCD) needs to connected to the programming port of
the SPLCD Display and communication verified (Base Unit “Who Am I”) before continuing.
1. Connect the Port labeled
SERIAL
on the rear of the SmartPAD LCD™ Panel –
Figure 3 Item #21
to the RS232422 Converter (not included) and then connect the DB9 port of the converter to the
corresponding component or device of the commands to be tested.
NOTE:
A “Null Modem” cable may be necessary for communicating with the Component or Device.
Please check with the Manufacturer to see if this is required.
2. Click on the ‘SPLCD Test’ button in the RS232 Palette Editor.
3. Make sure the RS232 Port Settings (Baud Rate, Parity, Data Bits, and Stop Bits) are set
appropriate for the device connected to (refer to the mfg’s Instruction Manual of the component or