A2L configuration:
Click
Open A2L file
(3)
and select the description file that corresponds
with the ECU.
The X
ORAYA
Suite reads the A2L file and configures the CCP
connection accordingly.
If
Overwrite alias with ECU name
under
Settings
(6)
is activated,
Alias
is also changed.
If supported by the A2L file, the X
ORAYA
Suite automatically runs an
EPK version check with the ECU and displays the result via the
Traffic light for the EPK check
(4)
.
You can also execute this check manually via the
EPK
button.
Levels of the
Traffic light for the EPK check
(4)
:
▪
green
check successful
▪
yellow
check not possible
▪
red
check not successful
Signal configuration:
Click
Open selection file
(5)
and select a suitable XML, CFG or LAB file.
or
Click
Signal selection
and select the signals manually. (
➔
The X
ORAYA
Suite calculates the expected percentage of the bus load
increase.
The result evaluation is displayed via the
Traffic light for the bus
load
(7)
.
Configure the levels of the
Traffic light for the bus load
(7)
:
Right-click on the traffic light and then on
Edit traffic light settings for
this interface type
.
Specify the percentage limit between green and yellow (standard: 50).
Specify the percentage limit between yellow and red (standard: 80).
Click
OK
.