2-18
•
Scan up to seven 4-digit pairings where the first 2 digits represent the
hex number to
replace
and the second 2 digits represent the hex
number to
insert
. You can have up to seven character reassignments.
•
Scan
SET
You can eliminate the output of a character by using
FF
as the hex number to
insert. For example, if you wanted to eliminate all
$
, following the above
instructions, enter
24FF
.
Beep Tone
Lowest 0
Low 1
Medium 2
High
3
Highest 4
No Beep Tone
5
Batteries
Alkaline Batteries
0
Rechargeables 1
•
In order to get an accurate
Battery Status
reading; you must select the
correct battery type. If you ordered NiMH batteries (part number L01)
with the RF Terminal, this will be set to Rechargeable before shipping.
•
If you didn't order re-chargeable batteries, this shipped setting is
Alkaline.
Battery Status
can be displayed by pressing the STATUS key
on the RF Terminal keypad.
•
Before you can recharge the batteries, this parameter must be set to
Rechargeables. Don't try to recharge alkaline batteries. They might
explode. This will void your warranty.
•
If you decide to use rechargeables after ordering the RF Terminal
without rechargeables included, you must change this setting allow
recharging.
Date Format
US Format
0
European Format
1
•
The US format of
mm/dd/yy
is the default setting.
•
If you switch formats, you must reset the date (
SET DATE
) in the new
format also.
Date/
Time
Speaker