2-14
2 of 5 Length
Default setting
06
Valid entries
00-98
To read variable length 2 of 5 codes
00
•
2 of 5 is so susceptible to misreads that the RF Terminal adds an additional
safeguard - it can be configured to look for fixed-length data only.
•
The default setting of
06
causes the RF Terminal to read
only
2 of 5
codes that are 6 digits in length. To set the RF Terminal to read a
different length, scan any two-digit number from the bar pad table. For
example, to change the RF Terminal to accept an 8-digit bar code, scan
0
then
8
from the bar pad table. 2 of 5 code must always be an even
number of digits so the length setting must always be an even number.
•
Reading variable length I 2of5 or 2 of 5 codes is to be avoided if at all
possible. The
00
setting is supplied for the purposes of reading codes
of unknown length, counting the digits and setting the length to the
proper number.
MSI and Plessey
Disable MSI
0
Enable MSI, 1 Mod 10 check digit
1
Enable MSI, 2 Mod 10 check digits
2
Enable MSI, 1 Mod 11/ Mod 10 check digit
3
Transmit no check digits
4
Transmit 1 check digit
5
Transmit 2 check digits
6
Enable Plessey bar code (mutually exclusive with MSI)
7
Enable LabelCode5 (mutually exclusive w/MSI & Plessey)
8
Enable LabelCode4 (mutually exclusive w/all above)
9
•
LabelCode5
and
LabelCode4
are proprietary bar code types used by
Follet.
•
If you have enabled the Mod 10 or Mod 11 check digits, they will be
transmitted along with your bar code data from the RF Terminal to your host.
•
For more information regarding MSI or Plessey Code, see
Appendix
K
;
MSI Plessey Code.
RSS-14
Disabled 0
14 digits with no identifiers, i.e. 10012345678902
1
14 identifiers, i.e. ]e00110012345678902
2
14 digits + UCC-128 format, i.e. ]C110012345678902
3
Bar
Codes
Bar
Codes