![Woodstock Shop Fox W1805 Owner'S Manual Download Page 17](http://html1.mh-extra.com/html/woodstock/shop-fox-w1805/shop-fox-w1805_owners-manual_995628017.webp)
-15-
Model W1805 (For Machines Mfd. Since 7/15)
SE
TU
P
Air.Connection
The air supply unit features a regulator, a filter, and a
lubricator (
Figure.10.&.11
). Each of these components
must be setup properly before operating the machine.
To.prepare.the.air.supply.unit.for.operation,.do.these.
steps:
1.
Connect your air hose to the air supply unit with a
standard
1
⁄
4
" NPT female quick-release coupler.
— If air leaks from the bottom of the filter, the
filter drain plug may be in "drain" mode. Move
the adjustment at the bottom of the filter to the
other side to put it in "plug" mode.
2.
Check the air pressure reading on the gauge. The
correct setting is 40 psi.
— If the setting is correct, skip to
Step.4
.
— If the setting is not correct, proceed to the next
step.
3.
Pull up on the regulator knob, rotate it in the
direction necessary until the gauge reads 40 psi,
then push the knob down to lock it.
4.
Adjust the lubricator by turning the lubrication
dial clockwise until it stops, then turning it
counterclockwise one full turn. (Further adjustments
can be made later as necessary.)
Figure.10.
Air regulator and filter
Figure.11.
Air lubricator features.
Regulator Knob
Filter
Filter Drain Plug
Lubrication
Rate Dial
Fill Plug
Lubrication
Rate
Window
Summary of Contents for Shop Fox W1805