8-12 Other Error Messages
Rev AB
Wolke m600 touch Operator Manual
Other Error Messages
E1211
‘Invalid Job File (EAN over 165 mm long)' - Barcode too
large - resize to maximum length of 165 mm - correct in
CLARiSOFT
®
Warning
E1212
‘Invalid Job File (Barcode Length Incorrect)' - Barcode
field does not have expected number of characters -
correct in CLARiSOFT
®
Warning
E1213
‘Invalid Job File (barcode out of limits)' - Barcode
overruns image area. Resize image area to
accommodate the barcode - correct in CLARiSOFT
®
Warning
E1000
‘Image Update Failure’ - CLARiTY
®
is unable to update
the image before receiving the next print signal since the
products are too close to each other.
Fault
E1001
‘Count Limit Reached’ - One or more fields in the image
design has reached the allocated end value.
Fault
E1002
‘Abort (Operation Aborted)’ - 'The operation of the
printer has been stopped by the host control system.
Fault
E1300
‘Slave Printer Absent’ - Communications between the
Master printer and the Slave have been lost - check
cabling.
Fault
E1301
‘Master Printer Absent’ - Master printer configured
incorrectly (Slave) - check configuration and cabling
Fault
E1302
‘Slave Job Select Failed’ - Communications between the
Master and Slave printer is lost - check cabling.
Fault
Message
Possible Cause
Solution
No printhead
installed
The job loaded in the print
memory requires more
printheads than connected
Reduce the number of heads in the job
or connect more printheads.
Faulty cable connection, faulty
plug-and-socket connector,
faulty printhead electronics
Check the connections between the
Wolke m600 touch and the printhead.
If the fault is not eliminated, contact the
persons in charge at Wolke.
Table 8-7: Other Error Messages