8-10 CLARiTY® Error messages
Rev AB
Wolke m600 touch Operator Manual
E1005
‘Print Limit Exceeded’ - The current job is selected with
a print limit (i.e. a limit on the number of times the job
can be printed). This limit has been reached but the
printer has received a further print signal that would
have exceeded the limit. This error clears after selecting
a new job. Alternatively, a job selection command or
variable data update from an external source also clears
this error.
Fault
E1006
‘Image Update Failure’ - CLARiTY
®
is unable to update
the image that is printed next. This usually occurs
because products are too close to each other. Touch the
Clear button to restart the printer.
Fault
E1007
‘Image Update Failure’ - CLARiTY
®
is unable to update
the image that is printed next. This usually occurs
because products are too close to each other. Touch the
Clear button to restart the printer.
Fault
E3013
‘Printhead Absent’ - Communications between
CLARiTY
®
and the printer have been lost, check the
cabling.
Fault
E3016
‘Printhead Volts Error’
Fault
E3024
‘24 Volt Error’ - The 24 volts supply is not in the working
range. Power the printer OFF and ON to try and clear
the fault. If the problem persists, call your maintenance
engineer or local service representative.
Fault
E3025
‘Printer Ambient Temperature’ - The internal ambient
temperature of the printer is outside its recommended
operating range. Touch the Clear button below to clear
this warning.
Warning
E3026
‘External Error’ - The operation of the printer has been
suspended by the control system. If the Clear button is
available below, you may touch it to clear this error and
resume printing.
Fault
E1100
‘Invalid Job File (Bad Field Reference)’ - Source field
reference incorrect - correct in CLARiSOFT
®
Warning
E1101
‘Invalid Job File (Missing Data Source Field)' - Job file
missing a data field - correct in CLARiSOFT
®
Warning
E1102
‘Invalid Job File (Duplicate Named Fields)’ - Field
names have been duplicated in Job File - correct in
CLARiSOFT
®
Warning
Error
No
Report on CLARiTY Operator Interface
Status
Table 8-6: CLARiTY
®
Error Messages (Continued)