8-8 Job Faults
Rev AB
Wolke m600 touch Operator Manual
Job Faults
Purging Faults
Cartridge Faults
Fault
Cause
Solution
The job cannot
be opened.
The job is not compatible with
this Firmware version.
The job must be newly created for this
Firmware version.
After a certain
number of prints
the Wolke m600
touch
automatically
switches to
OFFLINE.
A counter field is printed in
which the counter end value is
predefined and the Wolke m600
touch switches to OFFLINE
mode when this value is
reached.
Change the specifications for the job.
A limited print run has been
specified in the job settings.
Change the specifications for the job.
Table 8-2: Job Faults
Fault
Cause
Solution
No purge
operation
The purge pause setting may be
too long, i.e. the actual print
pause is not as long as the print
pause set in the purge menu.
Adjust the purge setting.
Table 8-3: Purging Faults
Fault
Cause
Solution
The
Ink empty
alarm is not
shown at output.
The Ink empty
alarm is not
configured on an output.
Reconfigure the outputs.
Table 8-4: Cartridge Faults