W5500S2E-S1 serial to Ethernet module
W5500S2E-S1 user manual
21
6.3.3
Serial configuration command list
Features
Command
Type
Max length
Parameters / Description
Serial port 1 parameters
AT+COM1
R/W
10
Parameters format:
[baud],[datab],[parity],[stopb],[c]
Default: 7,1,0,1,0
Baud rate
AT+C1_BAUD
R/W
2
0: 1200; 1: 2400; 2: 4800;
3: 9600; 4: 14400; 5: 19200;
6: 38400; 7: 56000; 8: 57600;
9: 115200 (default); 10: 128000;
11: 234000; 12: 256000; 13: 468000;
14: 921600; 15: 1152000
Data bit
AT+C1_DATAB
R/W
1
0: 7 bit 1: 8 bit (default)
Stop bit
AT+C1_STOPB
R/W
1
0: 0.5 2: 1.5
1: 1 (default) 3: 2
Parity bit
AT+C1_PARITY
R/W
1
0: none (default)
1: odd 2: even
Serial flow control
AT+C1_SER_C
R/W
1
0: none (default)
1: Hardware flow control
Clear out serial buffer
AT+C1_BUF_CL
S
R/W
1
Only available on TCP modes
0: Keeps data in serial after connection has
created (default)
1: Clear data in serial after connected has created
Data packaging (length)
AT+C1_SER_LE
N
R/W
4
Value range: 0~2048 byte;
Default: 0 (Disable data packaging by size)
Nagle algorithm wait time (ms)
AT+C1_SER_T
R/W
5
Value range: 0~60000, unit: ms;
Default: 0 (Disable data packaging by period)
Inactivity time (ms)
AT+C1_IT
R/W
5
Only available on TCP modes
Value range: 0 ~ 60000, unit: ms;
Default: 0 (disable this function)
TCP keep alive time (ms)
AT+C1_TCPAT
R/W
3
Only available on TCP modes
Value range: 0~255, unit 5s;
Default: 0 (disable this function)
TCP authentication
AT+C1_LINK_P
R/W
1
Only available on TCP server mode
0: No password is required for TCP connection
(Default)
1: Required password for TCP connection
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from