W5500S2E-S1 serial to Ethernet module
W5500S2E-S1 user manual
33
Maximum value: 4,294,967,295 bytes.
6.5
AT command configuration examples
6.5.1
Set into TCP server mode example
AT\r\n
OK\r\n
AT+ECHO=1\r\n
[ECHO] Value is: 1\r\n
AT+C1_OP=0 \r\n
[C1_OP] Value is: 0\r\n
OK\r\n
AT+IP_MODE=0\r\n
[IP_MODE] Value is: 0\r\n
OK\r\n
AT+IP=192.168.1.88\r\n
[IP] Value is: 192.168.1.88\r\n
OK\r\n
AT+C1_PORT=5000\r\n
[C1_PORT] Value is: 5000\r\n
OK\r\n
AT+EXIT\r\n
//Terminal check
//Echo ON
//Operating mode in TCP server
//Set into static IP mode
//Set local IP address
//Set the local port number
//Save the settings and switch to data mode