Subject to changes without notice !
Änderungen vorbehalten !
Gearless Lift Machine
WSG-SF
Operating Instructions
EN
Code: GM.8.004284.EN
Date:
28. Jan 2020
Version: 0.16
Page: 7
4. Handling
4.1. Transport and storage
•
Climate class: 2K3 according EN 60721
•
Transport temperature: -20°C bis +60°C, max. 20 K/hour fluctuated
•
Transport air humidity: max. relative humidity 85 % at 20°C (no moisture condensation)
•
The lift machines leave the factory in perfect condition after being tested. Make a visual check for any external
damage immediately upon their arrival on site. If any damage is found to have occurred in transit, make a notice of
claim in the presence of the carrier. If appropriate, do not put these machines into operation.
•
Do not expose the motor to any shocks or impact.
•
Observe the relevant safety regulations and take the centre of gravity into account when handling the lift machines.
•
Use only suitable transport and lifting equipment.
•
Check that the eyebolt are tightly fitted before using them.
If necessary, screw the eyebolt completely into the threaded hole
and tighten it only by hand.
Important!
Avoid lateral pulling.
ok
WARNING
f
The eyebolts are designed for the specified machine weight, i.e. additional loads must not be applied. Danger of
breakage!
4.2. Storage
•
Climate class: 2K3 nach EN 60721
•
Storage tempera ture: -20°C to +60°C, max. 20 K/hour fluctuated
•
Storage air humidity: max. relative humidity 85 % at 20°C (no moisture condensation)
•
Store the motors only in closed, dry, dust-free, well-ventilated and vibration-free rooms. Do not store lift machines in
the open air. Bright parts are not sufficiently preserved to withstand extended periods of exposure.
NOTICE
f
Avoid excessive storage periods (recommendation: max. one year).
f
After prolonged storage (>3 months), rotate the motor -
every
three month continuously - in both directions at a
low speed (< 20 min
-1
) to allow the grease to distribute evenly in the bearings. The ropes must not be fitted.
•
Measure the insulation resistance before initial operation of the machine. If the value has dropped below 1 kΩ per volt
of rated voltage, the winding needs to be dried (insulation meter voltage: 1,000 V DC).
Unpacking
•
Dispose of the packaging material in an environmentally friendly manner or reuse it.
•
Any special transport aids or shipping braces are left with the customer.
4.3. Disposal
•
The lift machines consist of different materials. A waste separation of those different material components has to be
done.
•
The disposal must be professional and environmentally friendly according to law.
Summary of Contents for WSG-SF Series
Page 111: ......