Mechanical installation
INTORQ | BA 14.0214 | 09/2017
28
1. Check the air gap "s
L
" near the bolts using a feeler gauge and compare the values to the values for "s
LN
"
in the table (
16).
If the measured value for "s
L
" (
16) is not within the tolerance, then the brake and the motor end shield
must be checked.
4.4.4
Cover ring assembly
Abb. 10
Cover ring assembly
1. Pull the cable through the cover ring.
2. Push the cover ring over the complete stator (1).
3. Press the lips of the cover ring into the grove of the stator and flange or the end shield.
NOTICE
Do not insert feeler gauge more than 10 mm between armature plate and stator!
NOTICE
Brakes without flange require a groove in the end shield for the lip of the cover ring.
Cover ring
Socket head cap screws
Stator
Armature plate
Flange (optional)
End shield
NOTICE
Cover ring with condensation drain hole:
Attach the cover ring so that condensation can drain through the hole.