Subject to changes without notice !
Änderungen vorbehalten !
Gearless Lift Machine
WSG-SF
Operating Instructions
EN
Code: GM.8.004284.EN
Date:
28. Jan 2020
Version: 0.16
Page: 100
Commissioning and operation
INTORQ | BA 14.0214 | 09/2017
39
6.2.2
Testing the hand-release functionality
Abb. 15
Turning direction of the lever
Motor and brake are de-energized.
14. Suspend Bowden cable (not included in the delivery package) and pull with approx. 800 N.
- The drive must be able to be turned freely. A low residual torque is permitted.
15. Release the lever.
- Torque must be available!
The preparations for commissioning are completed.
6.3
Commissioning
1. Switch on drive system.
2. Carry out a braking test.
NOTICE
❚
The hand-release is designed for activation via a Bowden cable.
❚
An individual brake circuit can only be released electrically.
DANGER
Danger: rotating parts!
The drive system must be free of loads. The motor must not run!
Summary of Contents for WSG-SF Series
Page 111: ......