Maintenance and repair
INTORQ | BA 14.0214 | 09/2017
42
7.2
Inspections
To ensure safe and trouble-free operations, the spring-applied brakes must be checked at regular intervals
and, if necessary, replaced. Servicing will be easier at the plant if the brakes are made accessible. This must
be considered when installing the drives in the plant.
Primarily, the required maintenance intervals for industrial brakes result from their load during operation.
When calculating the maintenance interval, all causes for wear must be taken into account,
41. For
brakes with low loads (such as holding brakes with emergency stop function), we recommend a regular in-
spection at a fixed time interval. To reduce costs, the inspection can be carried out along with other regular
maintenance work in the plant.
Failures, production losses or damage to the system may occur when the brakes are not serviced. Therefore,
a maintenance strategy that is adapted to the particular operating conditions and brake loads must be de-
fined for every application. For the spring-applied brakes, the maintenance intervals and maintenance oper-
ations listed in the table below must be followed. The maintenance operations must be carried out as
described in the detailed descriptions.
7.2.1
Maintenance intervals
Type
Time interval
for operating brakes:
for holding brakes with emergency stop:
BFK464-
R
❚
according to the service
life calculation
❚
or else every six months
❚
after 4000 operating hours
at the latest
❚
at least every 2 years
❚
after 1 million cycles at the latest
Maintenance
Inspections with assembled brake:
Inspections after the brake has been
removed:
❚
Check release function
and control
44
❚
Check the play of the rotor
gear teeth (replace worn-out
rotors)
44
❚
Measure the air gap
27
❚
Check for breaking out of the
torque support at the sleeves
and the armature plate
❚
Measure the rotor thick-
ness (replace rotor if re-
quired)
44
❚
Check the armature plate and
flange or end shield
- Levelness < 0.1 mm
- Max. run-in depth = rated
air gap for the size
❚
Check for thermal damage
of the armature plates or
flange (dark-blue
tarnishing)
Summary of Contents for WSG-SF Series