Subject to changes without notice !
Änderungen vorbehalten !
Gearless Lift Machine
WSG-SF
Operating Instructions
EN
Code: GM.8.004284.EN
Date:
28. Jan 2020
Version: 0.16
Page: 99
Commissioning and operation
INTORQ | BA 14.0214 | 09/2017
38
1. The switching contact for the brake must be open.
2. Remove two bridges from the motor terminals to de-energise the motor.
- Do
not
disconnect the supply voltage for the brake. Apply DC voltage to the brake.
3. Apply DC voltage to the brake.
4. Measure the AC voltage at the motor terminals. The measured level must be zero.
5. Close the switching contact for the brake.
- The brake is released.
6. Measure the DC voltage at the brake:
- After the over-excitation time (refer to bridge/half-wave rectifier,
35), the measured DC voltage
must correspond to the holding voltage (refer to Tab. 5). A deviation of ±10 % is permissible.
7. Check the air gap "s
L
".
- It must be zero and the rotor must rotate freely.
8. Check the switching status of the micro-switch (refer to table Tab. 6).
9. Open the switching contact for the brake.
- The brake is applied.
10. Check the switching status of the micro-switch (refer to table Tab. 6).
11. Switch off DC voltage for the brake.
12. Screw the bridges onto the motor terminals.
13. If necessary, remove the neutral conductor from the neutral point (step 2).
NOTICE
If the brake is connected to the neutral point of the motor, the PE conductor must also be con-
nected to this point.
Contact type
Connection
Brake released
Micro-switch closed
N/C contact
black / grey
yes
no
no
yes
NO contact
black / blue
yes
yes
no
no
Tab. 6:
Switching status of the micro-switch
Summary of Contents for WSG-SF Series
Page 111: ......