Maintenance and disposal
Revision: 04
5022-D029179
en-21
7.1 Maintenance
日本語
español
françai
s
italiano
english
deutsch
7
Maintenance and disposal
Read the general safety instructions before beginning work (see Chapter 2.7 "General safety
instructions").
7.1
Maintenance
7.1.1 Cleaning
Clean the motor with a grease-dissolving, non-aggressive detergent.
7.1.2 Checking the holding brake
The motor can be optionally equipped with a holding brake.
To ensure the permanent functioning of the holding brake, it has to be regularly applied and
checked.
- It is recommended that the holding brake is released and applied at least twice daily by
deactivating the controller.
- It is recommended that the holding torque M
4
of the brake is checked at least once a day.
Details can be found in chapter 6.2 "Holding brake".
7.1.3 Visual inspection
Perform a
monthly
visual inspection:
Check the motor and moving cables for damage.
Check whether the cable ends are completely labeled.
7.2
Start-up after maintenance work
Attach all safety devices.
7.3
Information on the lubricant used
7.4
Disposal
Dispose of the motor at the recycling sites intended for this purpose.
Observe the applicable national regulations concerning disposal.
A change of lubricant in motors of this design is not necessary. All motor
bearings, gearheads and threaded spindles are permanently lubricated at
the factory.