10.1.2 Attachment recommendation: Inox Design (IP66/67)
As the shaft end has a lower protection class (IP20), design measures should be implemented
in the unit to protect it from dust and spraying water (e.g. encapsulation in the unit). If this is not
possible, it is recommended that you use a drive with a higher protection class.
By default,
cyber
®
dynamic line Inox Design
features
- protection class IP66/67 on the cable outlet side
(B),
- protection class IP20 on the customer outlet
side (A).
To also achieve protection class IP66/67 at the
connection to the application, the following steps
are recommended:
Incorporate a circular groove (E) into the
mountable flange (C).
Insert an O-ring into the circular groove.
Screw the
cyber
®
dynamic line Inox Design
to
the mountable flange.
By tightening the screws, the O-ring is
squeezed and protection class IP66/67 is
ensured.
Dimensions and tightening torques can be
found in table "Tbl-2".
cyber
®
dynamic line,
Inox Design
Size
17
22
32
40
O-ring [mm]
15 x 0.5
20 x 0.5
30 x 0.5
38 x 1.0
Screws
4 x M1.6
4 x M2
4 x M2.5
4 x M3
Tightening torque
(A2-70) [Nm]
0.11
0.23
0.46
0.81
Tbl-2: Attachment of cyber
®
dynamic line, Inox Design