Assembly
cyber
®
dynamic line
en-14
5022-D029179
Revision: 04
5.1 Preparations
deutsch
english
italiano
français
español
日本語
5
Assembly
Read the general safety instructions before beginning work (see Chapter 2.7 "General safety
instructions").
5.1
Preparations
Clean/de-grease the output shaft / thrust tube of the motor with a clean, lint-free cloth
moistened with a suitable grease-dissolving but non-aggressive cleaning agent.
Dry all fitting surfaces to neighboring components in order to achieve the proper friction values
of the screw connections.
Check the fitting surfaces additionally for damage and impurities.
For all motors, use screws with property class A2-70.
Do
not
use washers.
5.1.1 Preparations for ALxx series (linear actuators)
Pressurized air may damage the seals of the motor.
Do not use pressurized air for cleaning the motor.
If present, the temperature sensors and rotor position encoders,
particularly Hall Effect sensors and encoders, can be damaged by
electrostatic discharge.
Observe the directives concerning ESD protection.
Improper assembly can damage the linear actuator.
Only install the linear actuator on level, no-vibration, rigid structures.
Ensure freedom of motion of the customer application.
Arrange the linear actuator and the application optimally with respect to
one other to avoid lateral forces and thus premature wear of the threaded
spindle.
Avoid lateral forces and bending torques on the screw.
Avoid banging and knocking the screw.
Moving outside the permissible stroke path, at both the minimum and
maximum position, will damage the threaded spindle.
Limit the stroke of the linear actuator using appropriate measures (e.g.
stops, buffers) for the extended and retracted end position.
These end stops must be dimensioned appropriately and be capable
of absorbing the kinetic energy of the moving parts, which may be
moving at high speeds.
Summary of Contents for cyber dynamic 17
Page 30: ......