5.4 Installing electrical connections
deutsch
english
italiano
français
español
日本語
5.4
Installing electrical connections
Electrically live components may result in electric shocks if touched
and can cause serious injuries and even death.
Observe the five safety rules of electrical engineering before starting
electrical installation work:
- Disconnect.
- Secure against being switched on again.
- Check that there is no voltage.
- Ground and short-circuit.
- Cover neighboring and electrified parts.
Before switching the voltage back on, check that all electrified parts are
equipped with suitable and undamaged contact protection.
Check that protective caps are on the plugs. If protective caps are
missing, check the plugs for damage and soiling.
Electric operation in moist areas may result in electric shocks and can
cause serious injuries and even death.
Carry out the electrical assembly only in dry areas.
Improperly routed cables can get damaged.
Make sure that the maximum power length of the power-carrying
connecting cable between motor and power electronics does not exceed
25m.
Route the feed line of the motor in such a way that a minimum bending
radius of 10 x outer diameter (mobile) or 3 x outer diameter (rigid) is
observed.
The cable specifications can be found in the dimensional drawing (5007-
...).
Avoid twisting the cable by more than ±30° over a length of 1 meter.
The maximum permissible tensile strain of the feed line can be found in
Table "Tbl-5".
Size
F
max
[N]
cyber
®
dynamic 17
10
cyber
®
dynamic 22
15
cyber
®
dynamic 32
17
cyber
®
dynamic 40
20
Tbl-5: Maximum permissible tensile strain