5
075-00
60706-208
SPECIFICATIONS
GENERATOR
MODEL WATTS*
VOLTS AMPS HZ PH RPM
PSS2
2000
20/240
50.0
60
3600
* Derate 6% for Natural Gas operation. Derate to
792 watts when operating on Natural Gas pressure
of 4-6 inches water column. Derate 3.5% per 000
feet elevation above sea level.
FUEL CONSUMPTION
NATURAL GAS
1000 BTU/CU FT
LP VAPOR
2520 BTU/CU FT
CF/HR
190
76.6
BTU/HR
190,000
194,000
GAL/HR
N/A
2.1
LBS/HR*
N/A
9.0
*
Based on full load operation.
ENGINE SPECIFICATIONS
Refer to engine operating and maintenance instruc-
tions.
** NOTICE **
When unpacking the generator set, be sure to in-
spect it carefully for freight loss or damage. If loss or
damage is noted at the time of delivery, require that
the person making the delivery make note of the loss
or damage on the freight bill, or affix his signature
under the consignor’s memo of the loss or damage.
Contact the carrier for claim procedures.
When loss or damage is noted after delivery, segre-
gate the damaged material, and contact the carrier
for claim procedures. Be sure to retain the packag-
ing material for carrier inspection.
“Concealed Damage” is understood to mean dam-
age to the contents of a package which is not evi-
dent at the time of delivery by the carrier, but wheich
is discovered later. The carrier or carriers are
responsible for merchandise lost or damaged in tran-
sit. The title to goods rests with the consignee when
generators are shipped F.O.B. factory, and only the
consignee can legally file a claim. Please note, most
carriers have a time limit for filing concealed damage
claims.
**** CAUTION ****
These units are shipped with oil. Be sure to check
oil levels before operating. See engine manufactur-
er’s instruction manual for recommended oil require-
ments before initial starting.
UNPACKING
. Carefully remove the carton.
2. After inspecting the engine-generator and trans-
fer switch for external physical damage, check
for the following items packed inside the carton.
a. Owner’s manual.
b. Engine manufacturer’s instruction manual.
3. Remove main frame hold down bolts. (4)
4. Unit can now be lifted from shipping pallet.
INSTALLATION
General Information
******************
***** WARNING *****
******************
Before proceeding with the installation be sure the
operation selector switch is in the stop position.
These engine generator sets are designed to be
mounted on a concrete pad outdoors only.
As an
option a prefab pad may be used as long as proper
attention is paid to site preparation to insure the unit
will not move after installation. The transfer switch is
mounted next to your electrical entrance or distribu-
tion panel inside or outside the building. Consult a
qualified, licensed electrician or contractor to install
and wire the transfer switch.
The installation must
comply with all national, state and local codes.
Before beginning the installation process check the
rating of the generator set and its transfer switch
rating. Be certain they can handle the intended
load and are compatible with the enterance voltage,
phase and current ratings. Plans for installation
should be prepared with proper attention to me-
chanical and electrical engineering detail to assure
a satisfactory system installation. The information
in this manual is offered only as a guide to finializing
your installation plans.
Summary of Contents for ULPSS12H4W/E
Page 1: ...11075 00 60706 208 INSTALLATION AND OPERATORS MANUAL PACKAGED STANDBY SYSTEM ULPSS12H4W E...
Page 10: ...11075 00 10 60706 208...
Page 18: ...11075 00 18 60706 208 AC AND DC GENERATOR SCHEMATIC...
Page 20: ...11075 00 20 60706 208 ENGINE GENERATOR SET LAYOUT ULPSS12H4W E...
Page 21: ...21 11075 00 60706 208 ENGINE GENERATOR SET PAD LAYOUT...
Page 23: ...23 11075 00 60706 208 DATE HOURS ITEM WORK PERFORMED MAINTENANCE LOG...