3-10
Original Instructions
TP-5418901-F
August 2020
3. Release the UP/DOWN Switch and OVERRIDE Switch when the desired height is
reached.
4. Push both switch guards back into position to protect the UP/DOWN and OVERRIDE
Switches.
Access the Cycle Count and Temperature with UP/DOWN Switch
The cycle count and temperature:
•
Can only be accessed using the Universal Control Box or PC Interface.
•
Cannot be accessed during manual operation
To access the cycle count and temperature:
1. Ensure the mast is nested and the UP/DOWN Switch is released.
2. Hold the UP/DOWN Switch in the down position. The cycle count and temperature inside
the Universal Control Box will alternately show on the Display.
Note: The cycle count drives periodic maintenance procedures. The cycle counter increments
every time the DOWN Limit Switch is released and then made again. This will occur anytime the
mast is raised approximately one inch or more and lowered to the fully retracted position.
The cycle count only updates when using the Universal Control Box or PC Interface. Manually
operating the mast will not adjust the cycle count.
3.5 PC Interface Operation
For information on operation using the PC Interface, contact The Will-Burt Company.