S
TILETTO
AL
O
PERATING
I
NSTRUCTIONS
TP-5418901-F
Original Instructions
1-29
August 2020
The D-TEC Features:
•
Two detection modes that operate simultaneously:
o
Electric Field (E-Field) detection to sense the presence of nearby high voltage
AC
o
Magnetic Field (H-Field) detection to sense the presence of nearby high current
AC
•
An LED Look-Up Light and an Ambient Light Sensor to ensure the Look-Up Light only
illuminates when it is dark
•
The D-TEC communicates over an RS-485 link with the Universal Control Box which
acts as the communications master. This means the Universal Control Box initiates all
communication. The D-TEC only allows or disallows the operator to extend the mast and
does not provide direct power to the mast. Both the D-TEC and the Universal Control
Box perform self-diagnostic routines each time the Mast System is powered up.
Specifications for the D-TEC are listed in Table 1-3.
Table 1-3 D-TEC Specifications
Functional Characteristics
Operational Parameters
Detection
Simultaneous AC Voltage (Electric Field) and
Electromagnetic and Electrostatic (Magnetic
Field) Detection
Minimum Voltage Detection
2.3 Kilovolts/Meter at 0° (Reduced with angle)
Look-Up Light
LED
Input Voltage
11 to 33 VDC
Power Requirements
12 VDC 10 Amps or 24 VDC 5 Amps
Operating Temperature Range -40°C to 71°C (-40°F to 160°F)
Duty Cycle
100%
For more information on the D-TEC, see