Electrically Install the Mast System
Power must be disconnected before connecting or disconnecting any system connector. For
example, power must be disconnected when connecting or disconnecting J1, J2, J3, and J4 on
the Universal Control Box.
To electrically install the Mast System:
1. Refer to Figure 2-8 for an overview of the system wiring, and to Figure 2-9 for the
Universal Control Box schematic (optional EMI filter shown).
Note: When using an optional EMI filter, customer power will connect through the Power
Cable Connector (P/N:
213075) at point “A” below. The EMI filter cable will install
between
point “B” below and J1 on the Universal Control Box.
When NOT using the optional EMI filter, customer power will connect through the Power
Cable Connector (P/N: 213075) directly at J1 on the Universal Control Box.
Figure 2-8 Stiletto AL Wiring (Not to Scale)
Customer Power through
Power Cable Connector
(P/N: 213075)
24-Pin Mast Sensor
Cable from J2 to J6
4-Pin Motor and Brake
Cable from J3 to J5
8-Pin Data Cable for
Optional Components
J5
J6
J7
Optional EMI
Filter Shown
A
B