S
TILETTO
AL
O
PERATING
I
NSTRUCTIONS
TP-5418901-F
Original Instructions
8-11
August 2020
Table 7-3 Warning Codes Continued
Warning
Code
Trigger
Condition
System Response
Latch Until
Possible Cause
0010
Invalid (or no)
response from
Temperature
Sensor
Temperature
Sensor Failure
Warning
(WRN 0010):
Allow all normal
mast functions
•
Valid
temperature
reading
received
- or -
•
5 OVERRIDE
Switch
activations
within 3
seconds
- or
–
•
System power
is cycled and
trigger
conditions
cleared
•
Temperature Sensor
failed and requires
replacement
•
Temperature Sensor
Wiring damaged and
requires repairs or
replacement
0020
Pulses not
detected
during mast
positioning
Pulse Counter
Warning (W0020):
Allow all normal
mast functions.
NOTICE:
Mast height readout
will be inaccurate.
•
Valid pulse
count detected
•
5 override
switch
activations
within 3
seconds
•
System power
is cycled and
trigger
conditions
cleared
•
Pulse counter
requires adjustment
or recalibration
•
Pulse counter failed
and requires
replacement
•
Pulse counter wiring
damaged and
requires repairs or
replacement
Continued