S
TILETTO
AL
O
PERATING
I
NSTRUCTIONS
TP-5418901-F
Original Instructions
8-7
August 2020
Table 7-2 Error (Fault) Codes Continued
Error
Code
Trigger
Condition
System Response
Latch Until
Possible Cause
0040
From Nested
position, Up
Switch active
for more than 2
seconds with no
Down limit
switch change
Down Limit Switch
Failed/Stuck Fault
(ERR 0040):
Disable the Motor
Outputs unless the
OVERRIDE Switch is
also active.
Can occur on
combination with ERR
0001 or ERR 0002;
indicated as ERR 0041 or
ERR 0042.
•
5 OVERRIDE
Switch
activations
within 3
seconds
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
Switch requires
adjustment or
recalibration
•
Switch failed and
requires replacement
•
Drive system damaged
0080
From Fully
deployed
position, Down
Switch active
for more than 2
seconds with no
Up limit switch
change
Up Limit Switch
Failed/Stuck Fault
(ERR 0080):
Disable the Motor
Outputs unless the
OVERRIDE Switch is
also active.
Can occur on
combination with ERR
0001 or ERR 0002;
indicated as ERR 0081 or
ERR 0082.
•
5 OVERRIDE
Switch
activations
within 3
seconds
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
Switch requires
adjustment or
recalibration
•
Switch failed and
requires replacement
•
Drive system damaged
0100
OVERRIDE
Switch has
been active for
an excessive
time period
Override Switch Stuck
Fault
(ERR 0100):
Ignore OVERRIDE
Switch input.
Note: This fault cannot be
overridden.
•
OVERRIDE
Switch is no
longer active
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
Switch is being held on
•
Switch is damaged
•
Water ingress may be
activating switch input
0200
Up and Down
Limit Switches
are active at the
same time (not
physically
possible)
Conflicting Up/Down
Limit Switch Fault
(ERR 0200):
Disable the Motor
Outputs unless the
Override Switch is also
active
•
Either switch is
no longer
active
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
Switch(es) require
adjustment or
recalibration
•
Switch(es) failed and
require replacement(s)
•
Cable or connection
failure
Continued
Summary of Contents for 711990491
Page 2: ......
Page 46: ...STILETTO AL OPERATING INSTRUCTIONS 1 32 Original Instructions TP 5418901 F August 2020 ...
Page 98: ...STILETTO AL OPERATING INSTRUCTIONS 7 2 Original Instructions TP 5418901 F August 2020 ...
Page 114: ...STILETTO AL OPERATING INSTRUCTIONS 9 4 Original Instructions TP 5418901 F August 2020 ...