CLEANING AND SANITIZING YOUR VESSI™ FERMENTOR & DISPENSER |
23
CLEANING AND SANITIZING YOUR VESSI™
FERMENTOR & DISPENSER
5
Open the faucet for 2-3 seconds
until clear liquid is being dispensed�
Turn the faucet handle off and on
a few times while the liquid flows
through the lines� This ensures that
the faucet is cleaned�* Liquid can
be collected in the pitcher or any
other container�
*If using a faucet from another
manufacturer, check their cleaning
instructions�
6
Allow the faucet and draft line
to soak for 15 minutes�
7
Turn the 3-way valve knob to the
LIQUID INJECTION position� Flush
the LIS until you hear bubbling in
the vessel� This should take
2-3 seconds� Turn the 3-way valve
knob to OFF� This will empty the
LIS of the liquid�
8
Reconnect the beverage port
cleaning line� Open the faucet
and let drain until all liquids are
removed� Make sure the pressure
in the vessel has reached 0 psi�
NOTE:
All liquid is removed when
CO
2
blows through the line� More
pressure may need to be added if
the pressure gauge reads 0 psi and
liquid is still present�
RINSING
1
Remove the 8" stainless steel cap,
gasket, and tri-clamp and place in
warm rinse water�
2
Repeat sections “Thorough
Cleaning of Vessel and Dispensing
Lines” and “Cleaning the Beverage
Lines” using warm rinse water
in place of brewers detergent
to thoroughly rinse the Vessi™
Fermentor & Dispenser�
NOTE: The 15 minute soak times are
not required for the rinsing process�