background image

 

 

 

 

 

 

 

 

 

 

 

PWG-TY 20L 

PWG-CT 10L 

INSTRUCTIONS MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PlanetsWater (Worldwide) Corp. Proprietor: Daniel C. Matthews

 

Specialized Atmospheric Imported Product’s (SAIP) Thai-China Corp. 

PWG-TY 20L Units Instructions Manual – English Version 1.0.4 © 2010 

Summary of Contents for PWG-CT 10L

Page 1: ...WG CT 10L INSTRUCTIONS MANUAL PlanetsWater Worldwide Corp Proprietor Daniel C Matthews Specialized Atmospheric Imported Product s SAIP Thai China Corp PWG TY 20L Units Instructions Manual English Version 1 0 4 2010 ...

Page 2: ...his manual 2010 1 Contents Ⅰ INTRODUCTION 1 II SAFETY NOTES 1 Ⅲ PRECAUTIONS 1 Ⅳ MAINTENANCE 2 Ⅴ HOW DOES YOUR ATMOSPHERIC WATER GENERATOR WORK 2 Ⅵ FEATURES OF ATMOSPHERIC WATER GENERATOR 4 Ⅶ OPERATING YOUR ATMOSPHERIC WATER GENERATOR 5 Ⅷ TROUBLE SHOOTING 15 Ⅸ TECHNICAL SPECIFICATIONS 18 ...

Page 3: ...ord before maintenance 7 Do not share the electrical socket with other high power consumption appliance 8 Always use correct replacement parts 9 Do not unplug power cord with wet hands 10 Use the enclosed water pipe kits to connect with city water input Do not use any old water pipelines to connect to the unit 11 When moving the machine please unplug the power cord and empty water in all tanks Do ...

Page 4: ... driven machine This means the machine totally depends on the level of humidity in the air and the right temperature to produce water Ideally the humidity level should be at least 50 or above to achieve the machine s optimum performance In places with lower humidity level the machine will still produce water but not as quickly nor as much as in places with high level of humidity In the house envir...

Page 5: ...nt children from burning themselves upon touching the water tap e Venturi Fan Newly designed Venturi type fan increases production efficiency and greatly reduce the noise during operation e Water Leakage Detector In case of any unexpected situation of water leakage the machine will stop working automatically and warning sound and flashing VFD will be heard and seen f Condensing coils The condenser...

Page 6: ...s fresh and clean and prevents from second pollution l Overheat Protector Overheat protector offers further protection for your machine In case of overheating in hot pot during heating process this protector will automatically shut off heating device m Novel and Noble Body The Planets Water Atmospheric Water Generator has a smaller and sleeker design compared to other AWGs in the market The unit i...

Page 7: ...INSTRUCTIONS MANUAL Please visit http www planetswater com for the latest version of this manual 2010 6 D INDICATION ...

Page 8: ...INSTRUCTIONS MANUAL Please visit http www planetswater com for the latest version of this manual 2010 7 ...

Page 9: ...the VFD is lit If the unit is required to be shut off keep POWER button pressed for 5 seconds Press POWER again to switch it on 2 Don t be alarmed when you don t obtain hot or cold water during the first few days of operation Only when the water level in the tanks reaches to the right level then the heating cooling mechanism will be triggered Generally the first heating cooling will start in ten t...

Page 10: ...ue Cool water adjustment range is between 4 10 7 Time for the filtration system replacement REPLACE on display will blink to remind user to clean or change filters Please refer to Filter Replacement for details After the cleaning or replacement is done keep pressing RESET till the REPLACE indication stops blinking Press RESET again to turn off REPLACE indication and to reset the replacement warnin...

Page 11: ...ZATION REPLACEMENT below 12 CLEANING AND REPLACEMENT OF FILTERS Recommended Timing for Filter Replacement It might be verified according to different water consumption The timing below is based on 10 liters water consumption per day 1 LF2 Carbon Filter or Nanometer Molecular Sieve 3 6 months 2 Pre Carbon Filter I 6 months 3 Pre Carbon Filter II 6 months 4 Reverse Osmosis Membrane 24 months 5 Post ...

Page 12: ...clean air filter regularly according to the air pollution situation in order to ensure optimum air supply Take off air filter from the side as shown in picture 1 1 1 1 1 2 1 1 3 Rinse in clean water to remove dirt and then put it back 1 1 1 1 1 2 1 1 3 2 Replacement 2 1 Replacing the filters 1 4 1 1 4 2 1 4 3 1 4 4 1 4 5 1 4 6 1 4 7 1 4 8 1 4 9 water ...

Page 13: ...Run the unit Press keep pressing HOT to unlock and press to release 2 L of solution each from faucet Shut down the unit Drain all remaining solution from hot water drain outlet at the back 2 5 Fill city water into bottom tank Turn on the unit and have it running automatically till top tank is full of water 2 6 Keep pressing HOT to unlock and press to release 2 L of water each from faucet Shut down...

Page 14: ...ase drain out 500ml of cool water before drinking usage If the machine is to be inactive for more than 5 days it is recommended to drain off water in all tanks and switch off the machine in advance For its reactivation please run the system to produce about 5 liters of water and drain off from the back drain outlets 4 4 If the machine was not in use for more than 7 days or it has been in continuou...

Page 15: ... tubing of bottom tank and make sure it is tight and secure Check the draining tubing at the back and make sure it is tight and secure Check the water collector is on correct position Problem Remaining water can not be drained out from the back outlets when cleaning top tank and hot tank Solutions Check water stopper inside water drainage to see if the outlet is removed Problem There is burning sm...

Page 16: ...larly to ensure the free air flow Problem The humidity indication on screen is different from the real room humidity level It is normal if the difference is in range of 5 more or less Make sure the machine and the individual Humistat are placed in same place Make sure that the Humistat sensor is not blocked covered or too close to the wall Problem The machine has excessive vibration or noise Make ...

Page 17: ...X 111 cm b Net Weight 48 kg d Technical Data Working Temperature 15 40 Working Humidity 35 95 Water Storage Capacity 18 Liters Hot Water Temperature 75 93 Cold Water Temperature 4 10 c Power Supply 220 240V 50Hz 220 240V 60Hz 100 120V 50Hz 100 120V 60Hz Power input 1000 1150W 900 1150W Heating Wattage 500 600W 500 600W Operation Power 450 500W 450 500W ...

Page 18: ...INSTRUCTIONS MANUAL Please visit http www planetswater com for the latest version of this manual 2010 17 Atmospheric Water Production Capacity ...

Reviews: