background image

 
 
 
 
 
 
 

Operating instructions   

Pallas Duo

 

 

Summary of Contents for Duo

Page 1: ...Operating instructions Pallas Duo ...

Page 2: ... Presentation 4 to 5 3 General installation notes 6 4 Installation instructions 7 5 Programming 8 6 Description of function 9 7 Wiring diagrams 10 to 11 8 Exploded diagrams 12 to 18 9 Fault finding 18 to 20 10 Appendix A 21 ...

Page 3: ...tener carefully in the presence of the deliveryman to ensure you that it was not damaged during transport The instructions described in this handbook must be respected to the letter Before starting to use the softener read entirely and carefully this handbook Handle your softener with care The Packaging can be fully recycled please dispose of it in a suitable place Here is some information which w...

Page 4: ...4 2 Presentation View of the Softener Salt lid Salt Storage Control timer Resin tanks Control Valve By pass bronze option Raw water inlet Treated water outlet Flexible tubes option Drain connection ...

Page 5: ...the valve program or initiate a regeneration Program button Regeneration Initiation button Indicator Valve in service diode alluminated Regeneration tonight diode flashing Flow Indicator The diode flashes when water is used Chlorinator option diode alluminated during Chlorination SERVICE BRINE DRAW AND SLOW RINSE SALT TANK REFILL INDICATION OF THE TANK IN SERVICE ...

Page 6: ...e that the power supply cannot be cut by a switch upstream of the installation If the electric cable is damaged it must be replaced by a qualified person 3 Existing plumbing It must be in good condition and not furred up In case of doubt it is preferable to replace it The installation of a prefilter is always advised 4 Water Temperature The temperature of water should not exceed 35 C and the insta...

Page 7: ...n for a few minutes until all of the pipes are rinsed of any residual foreign bodies solder remains Turn off the raw water feed tap and cold tap when water runs clear 7 Put the by pass valve in the service position and let the water run into the resin tanks When the water flow stops open a cold water tap and let run in order to purge the air remaining in the resin tank Repeat for the second resin ...

Page 8: ...of the programming mode corresponds to the system capacity The capacity is expressed in US gallons litres or in m3 format US metric or m3 For example 6500 litres The second stage allows the adjustment of the time of regeneration For example 2 Oclock in the morning The third stage is a calander day overide maximum number of days between 2 regenerations For example a regeneration at least every 7 da...

Page 9: ... regeneration cycle stage to be reached display flickering or reached and remaining time for this cycle fixed display Once all of the regeneration cycles are carried out the valve returns to the service position For example The regeneration is in stage 2 with twenty seven minutes remaining To step from one cycle stage to the next during regeneration press the key This will have no effect if the va...

Page 10: ...10 7 Wiring Diagram Up Flow ...

Page 11: ...11 7 Wiring Diagram Up Flow Chlorinator ...

Page 12: ...12 8 Exploded Diagram Power Head Up Flow Ref 28396 ...

Page 13: ...GEAR 9000 15 2 15172 SCREW FLAT HEAD 4 40 x 1 38 16 1 15199 GROUND PLATE 9000 9500 17 2 15372 THRUST WASHER 18 2 15692 SPACER 19 2 15810 RETAINING CLIP 20 1 16433 MICROSWITCH 21 1 17315 DRIVE NUT 9000 9500 22 1 18737 MOTOR 24V50HZ 1RPM 23 2 19160 SCREW 24 1 21271 SERIAL NUMBER LABEL 25 2 23250 WASHER SS LN 4 26 1 23474 LABEL ASSY BY 27 1 23653 06 TERMINAL BLOCK 06 POSITIONS 28 1 24934 TERMINAL BLO...

Page 14: ...14 8 Exploded Diagram Power Head Up Flow chlorinator ref 28363 ...

Page 15: ...TE 9000 9500 16 2 15372 THRUST WASHER 17 2 15692 SPACER 18 2 15810 RETAINING CLIP 19 1 16433 MICROSWITCH 20 1 16442 SCREW AUX SWITCH 21 1 17315 DRIVE NUT 9000 9500 22 1 17592 CAPACITOR 23 2 25651 TRANSFORMER 24 1 18737 MOTOR 24V50HZ 1RPM 25 2 19160 SCREW 26 1 21271 SERIAL NUMBER LABEL 27 1 23250 WASHER SS LN 4 28 1 23474 LABEL ASSY BY 29 1 23653 06 TERMINAL BLOCK 06 POSITIONS 30 1 23950 10 CHLORIN...

Page 16: ... 1 13497 AIR DISPERSER 3 1 14906 END PLATE 4 1 14928 END PLUG STUD 5 4 15137 SCREW HEX WASHER HEAD 10 24 X 3 8 6 1 28246 INJECTOR ASSEMBLY 9100 UF 7 1 28173 PISTON LOWER ASSEMBLY 9000 UF 8 1 25642 SEAL SPACER KIT 9000 91000 9 1 28241 VALVE BODY DISTRIBUTOR ADAPTOR 9100 10 1 24234 PISTON UPPER ASSEMBLY 9100 UF ...

Page 17: ... 1 1 18303 01 O ring 2 1 18569 Retainer tank seal 3 1 19054 O ring 4 1 40673 2nd tank adapter 5 1 40538 O ring retainer 32mm 6 1 61419 Distributor adapter kit 10 1 13304 01 O ring 7 2 13255 Clip 8 2 14202 01 Screw A 1 28243 07 Tube assembly 9100 for 7 tank 9 4 13287 01 O ring ...

Page 18: ...18 8 Exploded diagram Water meter assembly ITEM QTY PART No DESCRIPTION 1 1 19797 METER BODY ASSY TURBINE 2 2 19569 CLIP FLOW METER 3 2 13314 SCREW HEX WASHER HEAD 8 18 x 60 ...

Page 19: ...t A Improper salt setting A Check salt usage and salt setting B Excessive water in brine tank B See Problem n 6 4 Loss of water pressure A Iron buildup in line to water softener A Clean line to water softener B Iron buildup in water conditioner B Clean control valve and add mineral cleaner to resin bed Increase frequency of regeneration and or backwash time C Clogged resin C Contact your retailer ...

Page 20: ...lve controller does not function correctly B Change the controller 11 Loss of capacity A Increase in water hardness A Change the capacity of the softener B Concentration or quantity of salt insuffiscient B Break up any salt concretions Make sure that there is sufficient water level in tank C Clogged resin C Contact your retailer D Bad distribution preferential flow irregular surface of the bed D T...

Page 21: ...2 6 10 1 1667 190 19 13 3 10 6 1579 200 20 14 0 11 2 1500 210 21 14 7 11 8 1429 220 22 15 4 12 3 1364 230 23 16 1 12 9 1304 240 24 16 8 13 4 1250 250 25 17 5 14 0 1200 260 26 18 2 14 6 1154 270 27 18 9 15 1 1111 280 28 19 6 15 7 1071 290 29 20 3 16 2 1034 300 30 21 0 16 8 1000 310 31 21 7 17 4 968 320 32 22 4 17 9 938 330 33 23 1 18 5 909 340 34 23 8 19 0 882 350 35 24 5 19 0 857 ...