3.2 Replacing the top UV
a. Switch off the unit and unplug power cable from the main electricity.
b. Open top cover.
c. Remove screws on top end.
e. Disconnect UV connection pin. Pull out UV bulb.
f. Replace with the new bulb and close back the top cover.
3.3. Replacing the cool-water UV
a. Switch off the unit and unplug power cable from the main electricity.
b. Open top cover.
c. Remove foam cup of UV.
d. Remove black insulation cover.
e. Disconnect UV connection pin. Pull out UV bulb.
f. Replace with the new bulb and put back all parts.
4. Attention:
4.1. It is recommended to dispense not less than 3 liters of water every day.
4.2. If hot water is not dispensed for a long period, it is recommended to turn on heating
process for more than 30 minutes once a week. Keep pressing HOT button to
unlock and press
“ ” to release 500 ml of hot water from faucet.
4.3. If the machine was not in use for 2 to 5 days, please drain out 500ml of cool water
before drinking usage. If the machine is to be inactive for more than 5 days, it is
recommended to drain off water in all tanks and switch off the machine in advance.
For its reactivation, please run the system to produce about 5 liters of water, and
drain off from the back drain outlets.
4.4. If the machine was not in use for more than 7 days or it has been in continuous
operation for more than 4 months, please follow the steps in CLEANING,
STERILIZATION & REPLACEMENT to sterilize the system.
4.5. Switch off the power before draining out water from the back outlets.
Ⅷ
. TROUBLE SHOOTING
Problem: The UV WARNING light
blinks and with three short beeps.
Solution
: Check the ultraviolet device next to the top tank to make sure the bulb is lit
on and all wirings are correct. If the UV is not working, replace with new bulb by
following steps in CLEANING, STERILIZATION & REPLACEMENT.
Problem: The whole UV WARNING logo
blinks and with three short beeps.
Solution
: Check the ultraviolet device at cool water output to make sure the bulb is lit
on and all wirings are correct. If the UV is not working, replace with new bulb by
following steps in CLEANING, STERILIZATION & REPLACEMENT.