INSTRUCTIONS MANUAL
Please visit http://www.planetswater.com
for the latest version of this manual
© 2010
14
Problem
:
The machine does not work even after the power cord is plugged in.
Solution
: Check for power voltage and ensure that it is in the correct range for
operation. Make sure that the connection to the wall socket is tight and secure.
Problem
:
the indicator
“REPLACE” on VFD display is blinking with beeps.
Solution
: After a long period of operation, the filter might be over dirty and will be
replaced. Replace with a new filter by following steps in CLEANING, STERILIZATION
& REPLACEMENT. Reset the filtration warning time by following the 7th step in section
OPERATIONAL STAGE.
Problem: The system detected water leakage on base. The red logo
on
screen blinks and the system cannot produce water.
Solutions
:
•
Keep pressing POWER button immediately and unplug power cord.
•
Check all tubing of filtration system and make sure they are all tight and secure.
•
Check the tubing of bottom tank and make sure it is tight and secure.
•
Check the draining tubing at the back and make sure it is tight and secure.
•
Check the water collector is on correct position.
Problem: Remaining water can not be drained out from the back outlets when
cleaning top tank and hot tank.
Solutions
: Check water stopper inside water drainage to see if the outlet is removed.
Problem: There is burning smell from the machine and meanwhile hot
temperature indication has exceeded the preset.
Solutions
:
•
Keep pressing POWER button immediately and unplug power cord.
Stop draining immediately if you are on draining operation from the back. Wait and
continue draining until hot temperature is normal.
Problem: Water output from faucet is too small.
Solutions
:
•
Clean the filter net inside water faucet or replace with new one.
•
Replace with new check valve inside water faucet.
Problem: No hot or cool water output but only room temperature water only.
Solutions
:
•
The heating function will be activated only when top tank water level on the
screen is above two levels.
•
The
cooling function will be activated only when top tank water level on the
screen is above three levels