Select whether forwarding is permitted ("Permit") or denied ("Deny"). The
default value is "Permit".
Rate Limiter ID :
Select which rate limiter to apply on this port. The allowed values are Disabled
or the values 1 through 16. The default value is "Disabled".
Port Copy :
Select which port frames are copied on. The allowed values are Disabled or a
specific port number. The default value is "Disabled".
Mirror :
Specify the mirror operation of this port. The allowed values are:
Enabled:
Frames received on the port are mirrored.
Disabled:
Frames received on the port are not mirrored.
The default value is "Disabled".
Logging :
Specify the logging operation of this port. The allowed values are:
Enabled:
Frames received on the port are stored in the System Log.
Disabled:
Frames received on the port are not logged.
The default value is "Disabled". Please note that the System Log memory size
and logging rate is limited.
Shutdown :
Specify the port shut down operation of this port. The allowed values are:
Enabled:
If a frame is received on the port, the port will be disabled.
Disabled:
Port shut down is disabled.
The default value is "Disabled".
Counter :
Counts the number of frame which match this ACE.
Buttons
Save
– Click to save changes.
Reset
- Click to undo any changes made locally and revert to previous saved
values.
Upper right icon (Refresh, clear)
You can click them for refresh the ACL Port Configuration or clear them by
manual.