9.18 Heat output, Australia/New Zealand
C4 GB
6.10
6.20
10.10
10.20
Natural gas (AUS/NZL)
Convection burner
[MJ/h]
42
74
81
115
Boiler burner
[MJ/h]
41
74
71
122
Propane (AUS/NZL)
Convection burner
[MJ/h]
42
74
81
115
Boiler burner
[MJ/h]
41
74
71
122
G30/G31: Propane 3P* (referred to lower calorific value H
i
)
Convection burner
[kW]
11.5
21
22
31
Boiler burner
[kW]
11.5
19
20
31
*The heat output is up to 15% higher with 3B/P LPG.
C4 GS
6.10
6.20
10.10
10.20
Natural gas (AUS/NZL)
Convection burner
[MJ/h]
42
74
81
115
Propane (AUS/NZL)
Convection burner
[MJ/h]
42
74
81
115
G30/G31: Propane 3P
Convection burner
[kW]
11.5
21
22
31
*The heat output is up to 15% higher with 3B/P LPG.
9.19 Heat output, Japan
C4 GB
6.10
6.20
10.10
10.20
Natural gas 13A (JPN)
Convection burner
[kW]
11
-
20
-
Boiler burner
[kW]
11
-
18
-
Propane (JPN)
Convection burner
[kW]
11.5
-
21
-
Boiler burner
[kW]
11.5
-
19
-
C4 GS
6.10
6.20
10.10
10.20
Natural gas 13A (JPN)
Convection burner
[kW]
11
-
20
-
Propane (JPN)
Convection burner
[kW]
11.5
-
21
-
9.20 Heat output, Korea
C4 GB
6.10
6.20
10.10
10.20
LNG: Natural gas 13A (KOR)
Convection burner
[kW]
11
21
21
31
Boiler burner
[kW]
11
19
19
31
9 Technical data
Installation manual
78