Gas pipe connection
R 3/4"
R 3/4"
R 3/4"
R 3/4"
Supply flow pressure
[mbar]
20 (17 - 25)
20/25 (18 - 30)
29/37/50 (25 -
57.5)
29/37/50 (25 -
57.5)
Gas data (as per CE) at 15 °C and 1013 mbar dry
Lower Wobbe Index W
i
[MJ/m
3
]
45.7
(36.8 - 49.6)
37.4
(30.9 - 40.5)
70.7
(68.1 - 70.7)
80.6
(68.1 - 80.6)
Upper Wobbe Index W
S
[MJ/m
3
]
50.7
(40.9 - 54.7)
41.5
(34.4 - 44.8)
76.8
(72.9 - 76.8)
87.3
(72.9 - 87.3)
Lower calorific value H
i
[MJ/m
3
]
34
29.3
88
116.1
[MJ/kg]
-
-
46.3
45.7
Higher calorific value H
S
[MJ/m
3
]
37.8
32.5
95.7
125.8
[MJ/kg]
-
-
50.4
49.5
Exhaust gas extraction system
Air ventilation system with safety
shutdown
mandatory
mandatory
mandatory
mandatory
Exhaust gas values
CO
2
[%]
9.3 - 9.5
9.1 - 9.3
10.8 - 11.2
12.8 - 13.3
CO
[ppm]
< 500
< 500
< 500
< 500
9.10 Gas specification, The Netherlands
C4 GB/GS
Gas type
Natural gas 2H
(E)
Natural gas 2K**
Propane 3P
Liquefied gas
3B/P
Standard test gas, code
G20
G25.3
G31
G30/G31
Operating materials
Natural gas, liquid gas
x
x
x
x
Gas supply values
Gas pipe connection
R 3/4"
R 3/4"
R 3/4"
R 3/4"
Supply flow pressure
[mbar]
20 (17 - 25)
25 (20 - 30)
29/37/50 (25 -
57.5)
29/37/50 (25 -
57.5)
Gas data (as per CE) at 15 °C and 1013 mbar dry
Lower Wobbe Index W
i
[MJ/m
3
]
45.7
(36.8 - 49.6)
38.5
(37.2 - 38.9)
70.7
(68.1 - 70.7)
80.6
(68.1 - 80.6)
Upper Wobbe Index W
S
[MJ/m
3
]
50.7
(40.9 - 54.7)
42.7
(41.2 - 43.0)
76.8
(72.9 - 76.8)
87.3
(72.9 - 87.3)
Lower calorific value H
i
[MJ/m
3
]
34
29.9
88
116.1
[MJ/kg]
-
-
46.3
45.7
Higher calorific value H
S
[MJ/m
3
]
37.8
33.2
95.7
125.8
[MJ/kg]
-
-
50.4
49.5
Exhaust gas extraction system
Air ventilation system with safety
shutdown
mandatory
mandatory
mandatory
mandatory
Exhaust gas values
CO
2
[%]
9.3 - 9.5
9.1 - 9.3
10.8 - 11.2
12.8 - 13.3
CO
[ppm]
< 500
< 500
< 500
< 500
**Dit toestel is afgesteld voor de toestelcategorie K (I2K) en is geschikt voor het gebruik van G en G+ distributiegassen volgens de
specificaties zoals die zijn weergegeven in de NTA 8837:2012 Annex D met een Wobbe
‑
index van 43,46 – 45,3 MJ/m
3
(droog,
0 °C, bovenwaarde) of 41,23 – 42,98 (droog, 15 °C, bovenwaarde).
Dit toestel kan daarnaast worden omgebouwd en/of opnieuw worden afgeregeld voor de toestelcategorie E (I2E). Dit houdt der-
halve in dat het toestel: “geschikt is voor G+
‑
gas en H
‑
gas, dan wel aantoonbaar geschikt is voor G+
‑
gas en aantoonbaar geschikt
is te maken voor H
‑
gas” in de zin van het “Besluit van 10 mei 2016 tot wijziging van het Besluit gastoestellen….”
9 Technical data
Installation manual
74